HACH LANGE cuvette tests: Minimum amounts of reagents, maximum safety.

LCK341 Nitrite cuvette test 0.015- 0.6 mg/L NO2-N

Product ID: LCK341

Pre-dosed reagents for maximum safety. Easy to use and photometric evaluation, packaged in a fully equipped box. Officially approved for consent limits. Environmentally friendly due to less chemicals.

  • Precise and reliable measurement values
  • Maximum safety for users, thanks to the closed system and low amounts of reagents
  • Convenient and error-free dosing of the reagents
  • Barcode label for automatic recognition in the photometer
  • Differentiation between tests and measuring ranges by means of colour-coding

According to standardEN ISO 26777, DIN 38405 D10
Measuring range0.015 - 0.6 mg/L NO2-N
Measuring range- NO2-N
Measuring range (2)0.05 - 2 mg/L NO2
MethodDiazotisation
Number of tests25
ParameterNitrite
PlatformLCK
Shelf life24 months from production date
Standard methodEN ISO 26777
Storage conditions15 °C - 25 °C

Application notes

TitleLanguageSizeTypeSend to a friendDate 
A130 Sample Specific Blank Value
During a photometric analysis, in addition to the compounds listed in the interferences table, turbidity and colouration can lead to false results. These errors come either from the sample itself or arise from reactions with the reagents. The influence of the turbidity and/or colouration can be determined by establishing the sample specific blank value.
English, English869 KB PDF2013-03-21_logo

Data sheet/Brochures

TitleLanguageSizeTypeSend to a friendDate 
Colourcode - Cuvettes show their colours
More clarity through colourcoding; uniformly coloured packaging, cuvette labels and caps improve daily operations; new colour system quickly explained; 2 pages
English, English277 KB PDF2005-02-04_logo
LANGE cuvette test
Produkt Information: LANGE cuvette test, 2 pages with benefits, technical details: IBR, Integrated barcode reader, 10 fold measuremt system; chart of variety of paramters and measuring ranges
English, English163 KB PDF2006-08-24_logo

Methods/Procedures

TitleLanguageSizeTypeSend to a friendDate 
LCK341 Nitrite
Rev. P
French (Belgium), French (Swiss), French, French (Morocco), Dutch (Belgium), Dutch, German (Swiss), German, German, English, English, Italian (Italy)131 KB PDF2013-04-04_logo
Programming instruction for CADAS 100 LPG<gt/>=210, LCK 341 NitriteEnglish, English54 KB PDF2002-07-03_logo
Programming instruction for CADAS 100 LPG 158, LCK 341 NitriteEnglish, English165 KB PDF2002-07-03_logo

Practice Reports

TitleLanguageSizeTypeSend to a friendDate 
COD, Cost effective refilling of activated carbon filter
The leachate from a landfill in North Rhine-Westphalia, Germany, used to be transported by road tanker to the nearest sewage treatment plant. Since 1998 a biological treatment plant has been in operation, which has now handled more than 650,000 m3 of leachate, at a maximum rate of 350 m3/day. Four activated carbon filters, each filled with 20 m3, handle the residual COD load. The wastewater is fed into them in a sequence that depends on how long the activated carbon has been in use. A freshly regenerated filter discharges treated wastewater with a COD concentration of about 50 mg/l; this is well below the limit of 400 mg/l and is therefore a major cost factor. This can be avoided with the help of the COD cuvette test. 4 pages
English, English763 KB PDF2007-02-21_logo
LANGE cuvette tests used by the professionals for 40 years
The document reports of the advatages of the LANGE cuvette tests. Author: Dipl.-Ing. Petra Puetz, HACH LANGE Lab product specialist. The launch of the world s first ready-to-use reagent packages for photometric analysis in the 1960s had a substantial effect on environmental analysis. Today LANGE cuvette tests and photometers are indispensable elements of operational analysis. Innovations such as 10-fold rotational measurement have simplified analysis even further and made it more reliable. Quality assurance procedures (analytical quality assurance ADDISTA, round robin tests) are carried out and documented. The correct processing of used reagents in HACH LANGE s own certified environment centre completes the LANGE cuvette test-system. 8 pages
English, English1,189 KB PDF2007-09-18_logo
Nitrogen parameters: Nitrification, Denitrification
Author: Petra Puetz, HACH LANGE applications laboratory products specialist; The elimination of nitrogen compounds is a fundamental aspect of wastewater treatment. Nitrification and denitrification have to be controlled as efficiently as possible to ensure that outflow concentrations comply with the legal requirements. This is where analysis comes in, as enduringly stable and cost-effective plant operation depends on targeted and comprehensive measurements of the individual N parameters. The best results are obtained using a combination of laboratory analysis (cuvette tests) and process measurement technology (online sensors) at suitable measurement locations in and at the end of the wastewater treatment process. 4 pages
English, English400 KB PDF2013-01-04_logo

Accessories

  • available

ADDISTA Multi parameter standard solution

LCA707
  • available

LYW915 Rack for 16 LANGE round cuvettes or rectangular cuvettes 10 mm

LYW915
  • available

LCW919 Blank value cuvette set

LCW919