Solids VIS Benchtop offers high-speed wavelength scanning and many extras for simplified operation
DR 3800 VIS Spectrophotometer
Product ID: LPV424.99.00001
Compact, high-performance and reliable VIS Spectrophotometer with reference beam technology for routine analysis and user applications.
- Direct comparison of process and laboratory measured values with LINK2SC software
- Around 230 methods from screening to officially approved self monitoring
- User methods can be programmed easily with the help of intuitive menu guidance
- Clear and reliable operation with TFT colour display
- Use a USB Memory Stick to update the Instrument or Transfer Data
- OBSOLETE
| Accessories | Tungsten Lamp LZV565 Cuvette adapter 10 mm (A) LZV583 Cuvette adapter 1 inch (C) LZV584 Light shield LZV646 Cuvette adapter for Pour-Thru Cell (B) LZV585 Cuvette adapter set (cuvette adapters A, B and C) LZV647 Power supply, external LZV610 Power line EU LZV739 Power line UK LZV740 Power line USA LZV741 Power line China/Australia LZV742 USB-Memory Stick LZV568 USB-Interface Cable (1 m) LZV567 USB-Keyboard (keyboard layout: US) LZV582 USB-Barcode Scanner (hand-held scanner) LZV566 Pour-Thru Kit 5940400 Adapter Box LZV743 Cuvette set (1-inch rectangular cuvettes, matched pair in OS grade (10 mL) 2495402 Hach Data Trans (PC software for data transfer) LZY274 Certified test filter set for self-checks (Verification Kit) (6 precision glass filters with target values) LZV537 Dust cover HYH020 Filter pad A23766 Thermo printer PD 24, power line EU, USB cable, 1 roll of paper 5835900.00 Thermo printer PD 24, power line UK, USB cable, 1 roll of paper 5835900.82 Thermo printer PD 24, power line CH, USB cable, 1 roll of paper 5835900.51 Help Guide on USB memory stick LZV760 |
| Beam Height | 10 mm |
| Cuvette compatibility | 13 mm round cuvette 1" round cuvette 10 mm rectangular cuvette 50 mm rectangular cuvette |
| Data storage | 500 |
| Dimensions (H x W x D) | 144 mm x 368 mm x 359 mm |
| Display | 320 pixels x 240 pixels |
| Display | Color touch-screen |
| Display size | 111.4 mm x 83.5 mm |
| Display type | TFT |
| Includes | User manual, procedure manual on CD, line cord, installation instruction, cell adapter A, B, C and adapter box, dust cover |
| Max. Storage Humidity | 80 % |
| Max. operating humidity | 80 % |
| Operating Temperature Range | 10 to 40 °C |
| Operating mode | Transmittance (%), Absorbance and Concentration |
| Optical system | Reference beam, spectral |
| Photometric accuracy | 1 % at 0.50 to 2.0 Abs |
| Photometric accuracy | 5 mAbs at 0.0 to 0.5 Abs |
| Photometric linearity | < = 1 % at > 2 Abs with neutral glass at 546 nm |
| Photometric linearity | < 0.5 % to 2 Abs |
| Photometric measuring range | ± 5 Abs (wavelength range 340900 nm) |
| Power supply | 50 Hz - 60 Hz (input) |
| Power supply | 15 V 30 VA (output) |
| Power supply | 100 V - 240 V |
| Scanning speed | >= 12 nm/s (340-900 nm in steps of 1 nm) |
| Spectral bandwidth | 5 nm |
| Storage conditions | 40 °C to 60 °C |
| Stray light | < < 0.2 %T at 340 nm with KV450/3 |
| User interface | Bulgarian Chinese Croatian Czech Danish Dutch English Finnish French German Greek Hungarian Italian Japanese Korean Polish Portuguese - Brasilian Potuguese Russian Serbian Slovakian Slowenian Spanish Swedish Turkish |
| User programmes | 50 |
| Warranty | 2 years |
| Wavelength accuracy | ± 1.5 nm (wavelength range 340900 nm) |
| Wavelength calibration | Automatic |
| Wavelength range | 320 to 1100 nm |
| Wavelength reproducibility | 0.1 nm |
| Wavelength resolution | 1 nm |
| Wavelength selection | Automatic |
| Weight | 6.4 kg |
Data sheet/Brochures
Manuals
| Title | Language | Size | Type | Send to a friend | Date | |
|---|---|---|---|---|---|---|
| Additional Software LINK2SC® for DR 3800 (1st Edition)
Detailed user manual for the LINK2SC® software for comparing process and laboratory measurements directly in the DR 3800 spectrophotometer with pictures, screenshots and step by step instructions.
| English, English, French, French (Swiss), French (Belgium), German (Swiss), German, German, Italian (Italy), Spanish, Português | 1,487 KB | 2008-07-21 | |||
| Instruction sheet: Help Guide (en, de, fr, it, es)
Instruction sheet: Help Guide (en, de, fr, it, es)
| English, English, German, German, German (Swiss), Italian (Italy), French (Swiss), French, French (Belgium), Spanish | 453 KB | 2008-09-23 | |||
| USER MANUAL: DR 3800 Spectrophotometer
Edition 1
| English, English | 3,119 KB | 2008-05-30 |
Practice Reports
Software/Firmware
| Title | Language | Size | Type | Send to a friend | Date | |
|---|---|---|---|---|---|---|
| DR 3800 Spectrophotometer version: 1.07 / 36 / 66
Instrument Version 1.07 Progam Version HachLange 66: Update LCK307 / LCK311 / LCK323 / LCK332 Save the ZIP file to your PC or USB memory stick. Unpack the ZIP file and save the files to the USB memory stick. Please find more information in the README file enclosed in the download.
| English, English, German, German (Swiss), German | 1,801 KB | ZIP | 2013-04-22 | ||
| LCK364 Zirconium Update
Update LCK364 Zirconium for DR Spectrophotometer 1.Store the folder Zirkonium.zip to your PC 2.Unzip the folder and get the folder named Zirkonium 3.Open the folder Zirkonium and copy the folder used for your photometer to an USB stick: DR2800 / DR3800: dbhlc DR5000: dbhl DR6000: dbhlh DR3900: dbhlm 4.Update the software of your photometer according to the manual.
| German, German, German (Swiss), English, English | 13 KB | ZIP | 2013-03-25 |
Accessories
- available

2122800 Sample cell 1" with cap, round glass (10 mL) 25 x 60 mm, 1 piece
2122800- available

2427606 Round sample cell, 1", 10mL, glass (6 pcs with caps)
2427606- available

2401906 Glass sample cell 25 x 95 mm, 10-20-25 mL marks, 6 pieces with caps
2401906- available

2095100 SAMPLE CELL, 1CM MATCHED PAIR
2095100Consumables
- available

2429800 Nitrate Reagent Set, Powder Pillows, 0.01-0.50 mg/L NO3-N
2429800- available

2244100 Phosphate, ortho, Reagent Set 0.23-30.00mg/L PO4
2244100- available

2243900 Phenols Reagent Set, 0.002-0.200 mg/L
2243900- available

2243400 Molybdenum Reagent Set, Powder Pillows, 0-35.0mg/L Mo
2243400Successor
- available
- new

DR 3900 Spectrophotometer with RFID Technology, EU plug
LPV440.99.00001Service contracts
- available

TSE-CC-DR3800 Comfort contract for DR3800
TSE-CC-DR3800- available

TSE-BC-DR3800 Basic contract for DR3800
TSE-BC-DR3800- available

TSE-MC-DR3800 One-off inspection for DR3800
TSE-MC-DR3800