UV analysis-the reagent-free alternative: NITRATAX plus sc

NITRATAX plus sc Precise, self-cleaning UV nitrate process probe, 1 mm

Product ID: LXV417.99.10001

Reagent-free method. Multiple beam absorption photometer with a flash lamp, turbidity compensation through reference measurement. Lowered directly into the sample stream (flow-through unit optional).

  • UV absorption method-proven, continuous, and precise
  • Eliminates reagents, sampling, and sample conditioning
  • Self-cleaning probe
  • Measurement in activated sludge or in water
  • Life-long factory calibration

Stainless steel probe. UV beams are projected across a gap for immediate measurement of the nitrate content in water, wastewater and activated sludge. The measuring windows are cleaned by a wiper. Evaluation by SC controller. The simple mounting and easy handling of the probe is guaranteed by a specially designed tank rim mounting hardware. In order to place the controller near the probe, the tank rim mounting hardware for sc controller should be used. The through-flow variant is used wherever submersible installation is not possible for construction related reasons or the medium makes it necessary to measure a filtered sample (very high TS contents, sewage treatment plant inlet, etc.).

Accuracy± 3 % of measured value +0.5 mg/L (with standard solution)
Cable Length10 m fixed cable at sensor
Dimensions (D x L)70 mm x 333 mm
Measuring interval15 s to 30 min (fixed values selectable)
Measuring principleUV absorption measurement (patented 2-beam technique)
Measuring range0.1 - 100 mg/L NO2+3-N
Operating Temperature Range2 to 40 °C
Path Length1 mm
Pressure range0.5 bar
Resolution0.1 mg/L
Response time1 min
Weight3.6 kg

Data sheet/Brochures

TitleLanguageSizeTypeSend to a friendDate 
Nitrate Measurement - Nitrate probes with UV and ISE technology
HACH LANGE offers the right probe for every requirement thanks to a wide range optical and of ion selective process probes. Experience in the development and use of nitrate probes ensures familiarity with the practical requirements of sewage treatment plants of all sizes. From wasterwater and activated sludge to drinking water and low-cost trend measurements. A complete portfolio overview incl. technical data of NITRATAX plus sc, NITRATAX eco sc, NITRATAX clear sc and NO3D sc. 8 pages
English, English2,512 KB PDF2012-11-29_logo
Online measurements without investment costs
A new service from HACH LANGE: 24 hour long distance control; buy a measurement; all inclusive: reagents, parts and services; available for ammonium, nitrate and phosphate with SC 1000 controller, AMTAX sc, PHOSPHAX sc analysers, NITRATAX plus sc probe; 2 pages
English, English236 KB PDF2006-12-11_logo

Manuals

TitleLanguageSizeTypeSend to a friendDate 
Manual NITRATAX sc
NITRATAX sc - Probes for online nitrate measurement - Edition 5A
English, English495 KB PDF2012-08-24_logo

Practice Reports

TitleLanguageSizeTypeSend to a friendDate 
APPLICATION NITRATAX plus sc Adjustment of simultaneous nitrification /denitrification by nitrate concentration
With simultaneous nitrification / denitrification, organic carbon and ammonium-bound and nitrate-bound nitrogen are eliminated in a single tank. Either a circulating tank or a tank that can be considered to mix the medium thoroughly is used. Aeration can be regulated as a function of the ammonium-bound or nitrate-bound nitrogen. In operational practice, regulation by nitrate-bound nitrogen has been found to be the most favourable. It uses less aeration energy, and the risk of floating sludge in the final settling tank is low.
English, English510 KB PDF2004-08-19_logo
Cost savings with the latest control techology in Ladbergen
The WWTP of Ladbergen (Germany) is one of the top-performing plants of the region, although the inlet conditions are extremely difficult with a COD up to 3.000 mg/l. With significant rebuildings, process instruments by HACH LANGE and the modern control system Opti-Nox by KLEINE (engineering office in Germany) they achieved this position. In future they are going to save energy and further reduce wastewater fees. Author: Uwe Karg, Application process measurement technology HACH LANGE. 4 pages
English, English919 KB PDF2008-10-10_logo
NITRATAX plus/clear sc
Application NITRATAX plus/clear sc Measurement of nitrate concentration in mixing tanks / tower tanks
English, English338 KB PDF2004-08-03_logo
Optimal nutrient ratios for wastewater treatment
Author: Michael Winkler. For observing the legal requirements of treated wastewater, the operator of a wwtp has to manage the wastewater treatment process thoroughly to avoid exceeding the limit values. Among physical and chemical procedures the effluent treatment is based on the biological treatment by the microorganisms of the activated sludge. Therefore good knowledge of nutrient need and composition of the activated sludge is very important for operating at full capacity. Causes, consequences and counteractive measures for unfavourable nutrient ratio are described in this report; 8 pages
English, English972 KB PDF2013-01-02_logo
SBR REACTORS (SEQUENCING BATCH REACTORS)
Process optimisation of sequencing batch reactors with process measurement technology
English, English319 KB PDF2005-08-22_logo
Telemetry for the highest level of plant reliability
Author: Uwe Karg, Diplom-Ingenieur, chemistry, Application process measurement technology, HACH LANGE. Reliability is a main goal for control processes which have to reduce operating costs or ensure compliance with limit values. WWTP in Radolfzell (40.000 PE) at the Bodensee (Lake Constance) fullfil both requirements. Process measuring instruments supply the control system continuously with readings and signal their operational readiness by means of telemetry. Non-compliance with the limit values has been reduced significantly and the savings in added carbon amount to up to € 8,000 each year. 4 pages
English, English657 KB PDF2008-04-22_logo

Accessories

  • available

LZX848 Digital extension cable for SC sensors, 5m

LZX848
  • available

LZX148 Set of wiper blades 1mm (5 pieces)

LZX148
  • available

LZX012 Set of wiper blades 2 mm (5 pieces) for NITRATAX/UVAS

LZX012
  • available mid term
  • new

WTOS N/DN-RTC NH4-N & NO3-N, 1-channel, 90-240V AC, DINrail

LXV408.99.20101

Required Accessory

  • available

SC 1000 Display module with touchscreen

LXV402.99.00001
  • available

SC 1000 Probe module for 4 sensors, 4x mA OUT, Relay, EU

LXV400.99.2R121
  • available

SC 200 Digital Controller, 2x Digital, 2x mA OUT, EU cord

LXV404.99.20551

Consumables

  • available

LCW811 Cleaning solution, chlorine beaching, 500mL

LCW811
  • available

LCW828 Control standard, 25 mg/L NO3 (5.56 mg/L NO3-N), 1000mL

LCW828
  • available

NITRAX/NITRATAX Standard solution 50 mg/l NO3-N

LCW825
  • available

LCW826 Control standard, 100 mg/L NO3 (22.6 mg/L NO3-N), 1000mL

LCW826