• image description
  • image description
  • image description
  • image description

CLF10 sc: Free reagentless chlorine sensor

CLF10 sc Free chlorine sensor, pHD sensor, metric

Product ID: LXV45A.98.23022

Free chlorine sensor with pHD differential sensor (on panel)

  • Disinfection under control
  • Minimal operation costs
  • Plug and play
  • Real-time process control
  • EPA compliant according to Method 334.0

The Free Chlorine Analyser measures free chlorine continuously for real time process control. It is based on amperometric technology and is fully compatible with digital SC controllers. The analyser can be used in most municipal and industrial applications, and is best utilised where waste stream management is a constraint. The self diagnostics alerts you when the process has changed or the instument needs servicing.
Diagnostic features include the CAL WATCH algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow. All warnings are easy to configure.

AccuracyFree Chlorine: ± 3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit)
AccuracyTotal Chlorine: ± 20 % of the reference test* (DPD) at stable pH greater than 8.5
AccuracyTotal Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
AccuracyFree Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
Cable Length1 m (between gateway and SC controller)
Cable connection5 pin, M12 connector
Calibration method1-point or 2-point (zero and slope) calibration
CertificationsCE/ETL, EMC
Connection1/2 in ID
Connection1/4 in OD
Controller compatibilitySC controller platforms
Detection limit30 ppb (0.03 ppm) or lower
Dimensions (H x W x D)482.6 mm x 495 mm x 483 mm
Flow rate30 to 50 L/hour (7.9 to 13.2 gal/hour),Optimal is 40 L/hour (10.5 gal/hour)
InterferencesFree Chlorine: Monochloramine, chlorine dioxide, ozone, and chalk deposits. Total Chlorine: Chlorine dioxide, ozone and chalk deposits
MaterialPanel: Corrosion-resistant, fully-submersible (stainless steel, PVC, silicon rubber and polycarbonate)
Measurement MethodReagentless, electrochemical, three-electrode amperometric system
Measuring range0 - 10 ppm
Mounting styleFlat, vertical surface
Operating Temperature Range0 to 45 °C
Power Requirements (Voltage)12 V DC
Pressure range0.5 bar, no pressure impulses and/or vibrations
Repeatability30 ppb or 3%, whichever is greater
Resolution0.001 (1 ppb)
Response timeFree Chlorine: 140 seconds or less for 90% change (T90) at a stable temperature and pH
Sample temperature5 - 45 °C
Shipping weightApproximately 20 lbs
Storage conditions0 °C to 50 °C dry
Temperature compensationInternal temperature compensation in the sensor
Warranty12 months
Weight5.5 kg
Width19.5 in
Width495.3 mm

Data sheet/Brochures

TitleLanguageSizeTypeSend to a friendDate 
CLT10 sc / CLF10 sc: Total and free reagentless chlorine sensors
Data Sheet containing 4 pages with information and technical data of CLT 10 sc / CLF 10 sc - Amperometric sensor for free and total chlorine measurement
English, English308 KB PDF2010-06-23_logo

Manuals

TitleLanguageSizeTypeSend to a friendDate 
User Manual: CLF10sc und CLT10sc, Reagentless Chlorine Analyser
Edition 2
German, German, German (Swiss), French (Belgium), French (Swiss), French, French (Morocco), Dutch (Belgium), Dutch, Bulgarian, Česky, Danish, Spanish, English, English, Greek, Croatian, Hungarian, Italian (Italy), Polish, Português, Romanian, Russian, Swedish, Slovenian, Slovak, Turkish3,419 KB PDF2012-11-21_logo

Accessories

  • available

6122400 Digital extension cable 1 m

6122400
  • available

9181605 pH combination sensor, analogue, Ryton

9181605
  • available

9181505 phD differential analogue pH sensor, Ryton

9181505
  • available

9159900 Sample conditioning kit, with two pressure regulators

9159900