CLF10 sc: Free reagentless chlorine sensor
CLF10 sc Free chlorine sensor, pHD sensor, metric
Product ID: LXV45A.98.23022
Free chlorine sensor with pHD differential sensor (on panel)
- Disinfection under control
- Minimal operation costs
- Plug and play
- Real-time process control
- EPA compliant according to Method 334.0
The Free Chlorine Analyser measures free chlorine continuously for real time process control. It is based on amperometric technology and is fully compatible with digital SC controllers. The analyser can be used in most municipal and industrial applications, and is best utilised where waste stream management is a constraint. The self diagnostics alerts you when the process has changed or the instument needs servicing.
Diagnostic features include the CAL WATCH algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow. All warnings are easy to configure.
- available
- new
| Accuracy | Free Chlorine: ± 3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit) |
| Accuracy | Total Chlorine: ± 20 % of the reference test* (DPD) at stable pH greater than 8.5 |
| Accuracy | Total Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration) |
| Accuracy | Free Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration) |
| Cable Length | 1 m (between gateway and SC controller) |
| Cable connection | 5 pin, M12 connector |
| Calibration method | 1-point or 2-point (zero and slope) calibration |
| Certifications | CE/ETL, EMC |
| Connection | 1/2 in ID |
| Connection | 1/4 in OD |
| Controller compatibility | SC controller platforms |
| Detection limit | 30 ppb (0.03 ppm) or lower |
| Dimensions (H x W x D) | 482.6 mm x 495 mm x 483 mm |
| Flow rate | 30 to 50 L/hour (7.9 to 13.2 gal/hour),Optimal is 40 L/hour (10.5 gal/hour) |
| Interferences | Free Chlorine: Monochloramine, chlorine dioxide, ozone, and chalk deposits. Total Chlorine: Chlorine dioxide, ozone and chalk deposits |
| Material | Panel: Corrosion-resistant, fully-submersible (stainless steel, PVC, silicon rubber and polycarbonate) |
| Measurement Method | Reagentless, electrochemical, three-electrode amperometric system |
| Measuring range | 0 - 10 ppm |
| Mounting style | Flat, vertical surface |
| Operating Temperature Range | 0 to 45 °C |
| Power Requirements (Voltage) | 12 V DC |
| Pressure range | 0.5 bar, no pressure impulses and/or vibrations |
| Repeatability | 30 ppb or 3%, whichever is greater |
| Resolution | 0.001 (1 ppb) |
| Response time | Free Chlorine: 140 seconds or less for 90% change (T90) at a stable temperature and pH |
| Sample temperature | 5 - 45 °C |
| Shipping weight | Approximately 20 lbs |
| Storage conditions | 0 °C to 50 °C dry |
| Temperature compensation | Internal temperature compensation in the sensor |
| Warranty | 12 months |
| Weight | 5.5 kg |
| Width | 19.5 in |
| Width | 495.3 mm |
Data sheet/Brochures
| Title | Language | Size | Type | Send to a friend | Date | |
|---|---|---|---|---|---|---|
| CLT10 sc / CLF10 sc: Total and free reagentless chlorine sensors
Data Sheet containing 4 pages with information and technical data of CLT 10 sc / CLF 10 sc - Amperometric sensor for free and total chlorine measurement
| English, English | 308 KB | 2010-06-23 |
Manuals
| Title | Language | Size | Type | Send to a friend | Date | |
|---|---|---|---|---|---|---|
| User Manual: CLF10sc und CLT10sc, Reagentless Chlorine Analyser
Edition 2
| German, German, German (Swiss), French (Belgium), French (Swiss), French, French (Morocco), Dutch (Belgium), Dutch, Bulgarian, Česky, Danish, Spanish, English, English, Greek, Croatian, Hungarian, Italian (Italy), Polish, Português, Romanian, Russian, Swedish, Slovenian, Slovak, Turkish | 3,419 KB | 2012-11-21 |